Skip Navigation

Integrative and Comparative Biology 2002 42(1):174-181; doi:10.1093/icb/42.1.174
© 2002 by The Society for Integrative and Comparative Biology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (2)
Right arrow Request Permissions
Google Scholar
Right arrow Articles by Pratt, G. A.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?


Low Impedance Walking Robots1

Gill Andrews Pratt2,1
1 Franklin W. Olin College of Engineering, 1735 Great Plain Avenue, Needham, Massachusetts, 02492-1245

For both historical and technological reasons, most robots, including those meant to mimic animals or operate in natural environments,3 use actuators and control systems that have high (stiff) mechanical impedance. By contrast, most animals exhibit low (soft) impedance. While a robot's stiff joints may be programmed to closely imitate the recorded motion of an animal's soft joints, any unexpected position disturbances will generate reactive forces and torques much higher for the robot than for the animal. The dual of this is also true: while an animal will react to a force disturbance by significantly yielding position, a typical robot will greatly resist.

These differences cause three deleterious effects for high impedance robots. First, the higher forces may cause damage to the robot or to its environment (which is particularly important if that environment includes people). Second, the robot must acquire very precise information about its position relative to the environment so as to minimize its velocity upon impact. Third, many of the self-stabilizing effects of natural dynamics are "shorted out"4 by the robot's high impedance, so that stabilization requires more effort from the control system.

Over the past 5 yr, our laboratory has designed a series of walking robots based on "Series-Elastic Actuators" and "Virtual Model Control." Using these two techniques, we have been able to build low-impedance walking robots that are both safe and robust, that operate blindly without any model of upcoming terrain, and that add minimal control effort in parallel to their self-stabilizing passive dynamics. We have discovered that it is possible to achieve surprisingly effective ambulation from rather simple mechanisms and control systems. After describing the historical and technological motivations for our approach, this paper gives an overview of our methods and shows some of the results we have obtained.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.